champion
OPzS / OPzV Batteries
Energy Storage Rechargeable Tubular Plate OPzS battery solar battery
Description:
Champion OPzS batteries are designed with a combination of die-casting Tubular positive framework and superfluous electrolyte technologies to offer a very high lever of reliability and a long service life. Opzs batteries used special filter and proof design to ensure no acid fog runs over and burning proof, and also convenient examine and maintenance.
OPzS Batteries belong to the most enduring lead acid batteries. They are suitable for stand - by operations as well as for capacitive loads. They perfectly meet requirements for bridging times more than 10 h.
Applications:
Telecommunications
Power plant
UPS
Railroad Utility
Electric Utility
Photovoltaic Systems
Specifications:
Model | Voltage | Capacity | Dimension(mm) | Terminal | Terminal | Weight ±3%(Kg) | |||||
(V) | (Ah) | L | W | H | TH | Type | Position | Dry | Wet | Acid | |
OPzS 200 | 2 | 200 | 103 | 206 | 355 | 410 | F12 | 7 | 13 | 17.5 | 4.5 |
OPzS 250 | 2 | 250 | 124 | 206 | 355 | 410 | F12 | 7 | 15 | 20.5 | 5.5 |
OPzS 300 | 2 | 300 | 145 | 206 | 355 | 410 | F12 | 7 | 17.5 | 24 | 6.5 |
OPzS 350 | 2 | 350 | 124 | 206 | 471 | 526 | F12 | 7 | 21 | 28 | 7 |
OPzS 420 | 2 | 420 | 145 | 206 | 471 | 526 | F12 | 7 | 23 | 32 | 9 |
OPzS 490 | 2 | 490 | 166 | 206 | 471 | 526 | F12 | 7 | 26.5 | 37.5 | 11 |
OPzS 600 | 2 | 600 | 145 | 206 | 646 | 701 | F12 | 7 | 35 | 47 | 12 |
OPzS 800 | 2 | 800 | 191 | 210 | 646 | 701 | F12 | 8 | 48 | 64 | 16 |
OPzS 1000 | 2 | 1000 | 233 | 210 | 646 | 701 | F12 | 8 | 58 | 78 | 20 |
OPzS 1200 | 2 | 1200 | 275 | 210 | 646 | 701 | F12 | 8 | 68 | 92 | 24 |
OPzS 1500 | 2 | 1500 | 275 | 210 | 796 | 851 | F12 | 8 | 80 | 111 | 31 |
OPzS 2000 | 2 | 2000 | 397 | 212 | 772 | 827 | F12 | 12 | 110 | 152 | 42 |
OPzS 2500 | 2 | 2500 | 487 | 212 | 772 | 827 | F12 | 9 | 132 | 185 | 53 |
OPzS 3000 | 2 | 3000 | 576 | 212 | 772 | 827 | F12 | 9 | 159 | 222 | 63 |
Competitive Advantage:
Maintenance convenience;
Non-Spillable construction design;
Transparent containers, convenient to observe;
Special filter installation for acid fog proof;
High quality and high reliability;
Super long service life;
Special pole sealed technology;
Super reliability.
Battery Installation Guide
1. Point for attention during installation
(1) Reading is technical handbook prior to operation to ensure constructing correctly. Batteries shall be checked one by one to prevent from abnormal voltage prior to installation.
(2) Insulation tools should be used when installing & removing conductive connection slices due to higher serial voltage to protect from electric hit.
(3) During transportation & installation, battery’s short-circuit must be paid attention to because the battery delivered is electric.
(4) The battery with sealed free maintenance construction hasn’t changer of etching skin and eyes in normal case. Once sulphuric acid splashed in one’s eye’s rinsing with a plenty of water must be done and go to hospital.
(5) Exterior surface shall be washed with soap water and wet cloth .Dry cloth and duster shouldn’t be used, which can produce static to cause explosion, organic solvent shouldn’t be used either.
2. Installation of storage battery
(1) Battery may be installed in any direction (with the exception of turning upside down ) connection must be according to serial/parallel circuit. It is not allowable for incorrect and reverse pole connection.
(2) Oxides and dirty on battery’s terminals contact surface should be removed with sandpaper or iron brush to reduce contacting resistance and prevent from producing heat. A layer of vaselinum oil must be coated prior to installation. Check the system’s general voltage and positive & negative pole before power is on to ensure right installation.
(3) Shorten connecting cables if it is possible. Voltage drop produced should be taken consideration into selection of cables and for the cable’ specification, output capacitance shall not be as a unique factor.
(4) Battery may be shunted to reach its capacitance required. To reduce voltage drop, shunted connecting wire shall be most probably short.
(5) Batteries with different capacitance and /or performances and /or new & old degree shouldn’t be taken into service together.
(6) Battery should avoid installing inside on enclosed device. Good air ventilation is required. Don’t mount it nearby heat generating objectives e.g. transformer etc.
(7) Torque value for connecting battery shall be 11.3 N/M.
(8) Circuit switch shall be in position of “off” and the battery’s positive/negative pole shall be in that of corresponding connection of charger’s (load’s) positive/negative pole.
2v 600Ah OPzV Gel Tubular Plate battery for UPS Solar Wind Communication System
Description:
Voltage covers: 2V
Capacity: From 200Ah to 3000Ah
Designed floating service life: 20 years @ 20 °C/68 °F
The OPZV series stationary batteries are newly products which were developed at the end of 2005. The performances meet the standard DIN40742.
Characteristics
--- Gelled electrolyte, no flow, no leakage or no gradation of sulfuric acid.
--- The positive plate is tubular plate, which can effectively prevent the active materials from falling off.
--- PVC-SiO2 Separator, which is special for gel battery with tiny holes. The separator has high volume porosity, low electrical resistance and excellent wettbability.
--- Maintenance-free during the whole service life.
--- Low self discharge rate
--- Proof against deep discharge according to DIN43439 T5
CONSTRUCTION
- Positive plate – Tubular plate with die cast Pb-Ca alloy grid
- Negative plate – Balanced Pb-Ca grid for improved recombination efficiency
- Separator – leaf shape polymer separator
- Electrolyte – Dilute high purity sulphuric acid with fumed Silica gel
- Battery container and cover – ABS
- Pillar seal – 100% factory tested, proven two layers epoxy resin seal
- Relief valve – Complete with integrated flame arrestor
Applications
- Telecom
- Electric Utilities
- Control Equipments
- Security Systems
- Medical Equipments
- UPS systems
- Railroad Utilities
- Photovoltaic Systems
- Renewable Energy System
Specifications:
Model | Voltage | Capacity | Dimension(mm) | Terminal | Weight | |||
(V) | (Ah) | L | W | H | TH | Type | Kg±3%) | |
OPzV 200 | 2 | 200 | 103 | 206 | 355 | 390 | F12 | 20 |
OPzV 250 | 2 | 250 | 124 | 206 | 355 | 390 | F12 | 24 |
OPzV 300 | 2 | 300 | 145 | 206 | 355 | 390 | F12 | 28 |
OPzV 350 | 2 | 350 | 124 | 206 | 471 | 506 | F12 | 31 |
OPzV 420 | 2 | 420 | 145 | 206 | 471 | 506 | F12 | 35 |
OPzV 500 | 2 | 500 | 166 | 206 | 471 | 506 | F12 | 41 |
OPzV 600 | 2 | 600 | 145 | 206 | 646 | 681 | F12 | 49 |
OPzV 800 | 2 | 800 | 191 | 210 | 646 | 681 | F12 | 65 |
OPzV 1000 | 2 | 1000 | 233 | 210 | 646 | 681 | F12 | 80 |
OPzV 1200 | 2 | 1200 | 275 | 210 | 646 | 681 | F12 | 93 |
OPzV 1500 | 2 | 1500 | 275 | 210 | 796 | 831 | F12 | 117 |
OPzV 2000 | 2 | 2000 | 397 | 212 | 772 | 807 | F12 | 155 |
OPzV 2500 | 2 | 2500 | 487 | 212 | 772 | 807 | F12 | 192 |
OPzV 3000 | 2 | 3000 | 576 | 212 | 772 | 807 | F12 | 228 |
Competitive Advantage:
Maintenance free
Non-Spillable construction design.
Transparent containers, convenient to observe.
Special filter installation for acid fog proof.
High quality and high reliability.
Super long service life.
Special pole sealed technology.
Super reliability.
Maintenance-free regarding water refilling – due to innovative Gel-technology
Very high expected service life – due to optimized lead-calcium alloy
Very high cycle stability – due to tubular plate design
Maximum compatibility – design according to DIN 40742
Optimal space utilization – due to horizontal arrangement and stacking
Higher short-circuit safety even during the installation